Product basic info
Instruction manual languages: Dutch, English, French, German, Polish, Portuguese, Spanish
Primary colours: Black
Additional colours: Red
Depth unit: 40 mm
Height unit: 190 mm
Width unit: 100 mm
Weight unit: 300 g
Material: ABS
Physical properties
Cable length: 0.75 m
Display height: 36 mm
Display width: 62 mm
Display type: LCD
Backlight: Yes
Maximum digits display: 1999
Electrical data
AC current:
- basic accuracy: ± (1.5% rdg + 3 digits), ± (2.0% rdg + 3 digits) for 200mA range, ± (2.5% rdg + 5 digits) for 15 A range
- overload protection: 500 mA / 600 V, 15 A / 600 V fuse
- frequency range: 40-500 Hz
AC voltage:
- basic accuracy: ± (0.8% rdg + 3 digits) , ± (1.2% rdg + 3 digits) for 600 V range
- input impedance: 1 megohm for 2 V range, 10 megohm for other ranges
- frequency range: 40-500 Hz
- maximum input: 600V DC or AC rms
- test A:
- test B: >= or >=
Audible continuity measurement: Yes
Audible continuity:
- built-in buzzer sounds if resistance is less than 50 Ohm
- test voltage: approx. 3 V
Automatic polarity indication: Yes
Capacity:
- basic accuracy: ± (2.5% rdg + 10 digits) for 2000 pF range, ± (2.5% rdg + 5 digits) for 20nF to 20 µF range, ± (5.0% rdg + 10 digits) for 200 µF range
- overload protection: 500 mA / 600 V fuse
DC current:
- basic accuracy: ± (1.2% rdg + 2 digits), ± (1.5% rdg + 2 digits) for 200mA range, ± (2.0% rdg + 3 digits) for 15 A range
- overload protection: 500 mA / 600 V, 15 A / 600 V fuse
DC voltage:
- basic accuracy: ± (0.5% rdg + 2 digits) , ±(0.8% rdg + 2 digits) for 600 V range
- input impedance: 10 MOhm
- maximum input: 600 V
- overload protection: 600 V DC or AC rms
Diode test: Yes
Diode test specifications: test voltage: approx. 3 V (reversed DC voltage)
Frequency:
- basic accuracy: ± (2.0% rdg + 5 digits)
- overload protection: 600 VDC or AC rms
- sensitivity: sine wave 0.5 V rms
Fuse type: F 0.50 A / 600 VAC / 500 VDC, 5 x 20 mm, breaking capacity 1 kA, F 15 A / 1000 VAC / 1000 VDC, 6 x 32 mm, breaking capacity 10 kA
Out of range indication: Yes
Temperature measuring Celsius specifications:
- -50 - 150 °C / 150 - 800 °C
- basic accuracy:
- ± (3 °C + 3 digits) for -50 - 150 °C range
- ± (3 % + 3 digits) for 150 - 800 °C range
- overload protection: 500 mA / 600 V fuse
- NiCr-NiSi sensor
- K thermocouple probe: included
Transistor test: No
AC current measurements: 15 A, 2 mA, 20 mA, 200 µA, 200 mA
AC voltage measurements: 0-2 V, 20 V, 200 V, 600 V
Capacity measurements: 2 µF, 20 nF, 200 µF, 200 nF, 2000 pF
DC current measurements: 0.2 mA, 15 A, 2 mA, 20 mA, 200 µA, 200 mA
DC voltage measurements: 0-200 mV, 2 V, 20 V, 200 V, 600 V
Frequency measurements: 20 kHz
Resistance measurements: 0-200 Ω, 2 kΩ, 2 MΩ, 20 kΩ, 20 MΩ, 200 kΩ, 200 MΩ
Resistance specifications:
- basic accuracy: ± ( 1.0% rdg +3 digits) for 200 Ohm range, ± (1.0% rdg + 2 digits) for 2 KOhm to 2 Mohm range, ± (1.5% rdg + 3 digits) for 20 MOhm range, ± (5.0% rdg + 5 digits) for 200 MOhm range
- overload protection: 600 VDC or AC rms
Technical data
Safety rating: Cat III / 600 V, Cat IV / 300 V
Voltage tester type: AC / DC
Automatic power-off function: Yes
Pollution degree: 2
Data-hold function: No
Environmental data
IP rating: IPx0
Usage location: Indoor only
Operating temperature °C: 0-40 °C
Operating temperature °F: 32-104 °F
Storage temperature °C: -20-60 °C
Storage temperature °F: -4-140 °F
Maximum storage humidity: Maximum operating humidity: Operational properties
Measuring temperature range °C: -50-800 °C
Range setting: Manual
Power supply
Batteries included: Yes
Number of batteries: 1
Low battery indicator: Yes
Battery composition: Alkaline
Battery IEC size: E (6LR61, 6LP3146, 6F22, 6KR61, 6HR61 ,1604A, 1604D, 1604LC, 7.2H5, 11604, 11604M, PP3, 9-volt, 006P, MN1604)
Included
Set contents: test lead probe : CAT III 1000 V / CAT IV 600 V, 15 A, L = 75 cm
(EN)